INSTALLATION INSTRUCTIONS FOR LOW VOLTAGE STEP & BRICK
LIGHTS
(NOTE: This installation instruction applies to both rectangular and round
housing step lights)
FOR USE ONLY WITH LOW VOLTAGE LANDSCAPE POWER UNITS THAT DO NOT
EXCEED 25 AMPS, 15 VOLT MAX.
WARNING: Fixture must be
installed in accordance with local codes of the National Electrical Code (NEC).
Failure to do so may result in serious injury and/or damage to the fixture.
SAFETY WARNING: Fixture can become very hot depending upon the lamp
wattage used. Lens and metal around the lamp can become hot enough to blister
hands. Particular care should be take no to locate fixtures where small children can
reach them if high wattage lamps are used.
LUMINARIES ARE NOT TO BE INSTALLED WITHIN 10 FT. (3.05 M) OF A POOL OR SPA.
TOOLS REQUIRED FOR INSTALLATION:
Phillips Screwdriver
Wire Stripper
Flat Blade Screwdriver
Cutting Saw
Drill
INSTALLATION IN EXISTING WALLS / WOOD DECKS:
To prevent electrical shock, disconnect transformer from electrical supply before
installation or service.
Remove the reflector assembly from fixture.
Using the fixture housing / junction box as a template, mark the location of the box on
the wall.
Cut hole in wall to accept the housing / junction box. NOTE: Remove any insulation within six (6) inches of where box will be
installed.
Insert junction box into cut hole and secure tightly against wall.
Using the two (2) blue wirenut connectors (supplied), connect the wire leads from behind
the reflector to the 18-2 cable pigtail (also supplied) exiting the junction box (see
figure).
Install reflector and lamp.
Install cover plate to junction box and tighten screws (see figure).
Strip the two (2) leads from the fixture wire. Using the two (2) silicone filled
safety connectors (supplied) connect the leads from the fixture to the main supply cable
leads (see figure).
INSTALLATION IN MASONRY OR CONCRETE WALLS:
Remove the reflector assembly from fixture.
Build wood service frame and secure fixture housing / junction box to service frame.
NOTE: Optional mounting brackets for some models are available to facilitate installation
in concrete walls.
Remove 1/2 inch knockout from the side or bottom of housing / junction box.
Using 1/2 inch cable connector (supplied by others) pull supply wire through into
housing.
Cover opening of fixture with cardboard and be sure all unused electrical plugs
(knockouts) are closed before concrete pour.
Pour concrete.
Follow steps 6 through 9 above.
IMPORTANT SAFETY INSTRUCTIONS:
LIGHTED LAMP IS HOT!!
WARNING: TO REDUCE THE RISK OF FIRE, OR INJURY TO PERSONS:
Turn off / unplug and allow to cool before replacing lamp.
Lamps get HOT quickly! Contact only switch/plug when turning on.
Do not touch hot lens, guard or enclosures.
Keep lamp away from materials that may burn.
Do not touch the lamp at any time. Use a soft cloth. Oil from skin
may damage lamp.
Do not operate luminare fitting with a missing or damaged shield (cover).
SAVE THESE INSTRUCTIONS
LAMP INSTALLATION / REPLACEMENT:
CAUTION: Do not exceed maximum wattage marked on fixture label.
To prevent electrical shock, disconnect transformer from electrical supply before
service.
Loosen cover screws and remove cover.
Remove O-Ring (if available - some models do not include O-Ring).
Replace lamp with correct wattage and type of lamp marked on fixture label. NOTE: DO NOT touch Halogen lamp with bare hands. always use the
plastic bag provided to handle the lamp.
Clean O-ring and channel and re-install O-Ring (if applies). NOTE: O-ring channel must be cleaned and free of debris before replacing
cover.